This pipe is responsible for routing hot water released from the tpr to a proper discharge location.
Water heater discharge pipe pvc.
The valve should be connected to a discharge pipe also called a drain line that runs down the length of the water heater tank.
Local building codes vary but most require a catch pan under the water heater with a discharge pipe that ends above the rim of the pan to provide an air gap between the pipe and a pan full of water.
You may have an issues with the hot water coming out of overflow pipe.
The correct plastic pipe called for in this installation is called cpvc.
In contrast modern high efficiency condensing furnaces exhaust much cooler gasses and need only plastic pipe materials such as pvc cpvc or abs for their exhaust vents some high efficiency furnaces also include a plastic pipe for intake area and all types.
Where do i find the water heater in a mobile home.
Gas water heater power vent induced draft gas water heater pvc pipe exterior terminations.
Here s the quick rundown.
Scalding water and steam escape the tank through the valve and tube to relieve the pressure.
Instead it is attached with a discharge pipe link with hot water heater.
Pvc is a thermoplastic and therefore at some point it will begin to degrade and break down as it s heated up it just so happens that schedule 40 pvc s maximum operating temperature is 140 degrees fahrenheit around the same.
8 termination of the tpr drain pipe cannot be more than 6 inches or less than two pipe diameters above the floor ground or waster receptor.
This temperature pressure relief valve is not directly attach with the hot water pressure heater.
This is one of the most common questions people ask about using pvc pipe.
Can i use pvc for hot water.
Select 2 to 4 items to compare.
What does it mean when a water heater temperature pressure relief tpr discharge pipe is trapped.
Water heater pressure relief valve hot water recirculating pump white water heater accessories rheem water heater accessories rheem 50 gal parts rheem gas igniter.
If this very hot water exiting under force crashes into pvc pipe it will damage the glue weld soften and deform the pipe and destroy it in short order.
Again check the manual but some of the most common water heater power vent pvc pipe requirements are.
Cpvc is rated for hot water heater installation.
Does a tankless water heater in an attic require a drain pan.
Water heater tpr valves are commonly set to blow just under 210.
How doers get more done.
A trapped tpr dischage pipe is a common defect when a replacement water heater s tpr valve is lower than the original one and the installer connects to the exisitng discharge piping at the wall.
Horizontal exhaust outlet 12 minimum above the ground or expected snow level for cold climates.